UPS Centralized Power Supply Access Control Battery Charge Backup

UPS Centralized Power Supply Access Control Battery Charge Backup - offering reliable power backup solutions for factories. Contact us for a quote today.
Request a Quote

PRODUCTS DETAILS

Basic Info.

Model NO.
YSI-20
N.W.
1380g
Output Frequency
/
Experience
20 Years′experience
Output Voltage
5-36V
Output Type
Multiple
Output Power
1 - 50W
Input Voltage
110-240VAC 50/60Hz
Transport Package
1PC/PE Bag+White Box, , 36*23.6*25.5cm/50PCS/CTN
Trademark
YingJiao
Origin
Zhejiang, China

Product Description

 UPS Centralized Power Supply Access Control Battery Charge Backup

Product Description
Model: YSI-20
Power: 20W max.
Input: 110-240VAC 50/60Hz
Output Voltage: 5-36V
Output Current: 0.01-4A
Input current: 0.5A max.
Inrush Current: Cold start 45A. at 240VAC/50Hz,full load
Leakage Current: 2mA max. at 240VAC input
Protections: Short Circuit /Over Current /Over Voltage
Short Circuit Protection (SCP): Protection to Zero Voltage
Over Voltage Protection (OVP): ≤Vout*150%
Over Current Protection (OCP): 110%-180%
Working TEMP.: -20°C-60°C
Working Humidity: 20%-90% RH non-condensing
Storage TEMP.,Humidity and altitude: -40 ~+70°C ambient temperature and a 5% to 95% relative humidity range throughout an altitude range of -60 meters to +5000 meters AMSL. 
Certificates and approvals: CE,EMC,FCC,CCC,RoHS,REACH
EMI EMISSION: Radiation Test&Conduction Test: EN 55022/FCC Part 15
Harmonic Test : EN 61000-3-2
Flicker Test : EN 61000-3-3
SAFETY STANDARDS: EN 60950-1:2006+A11:2009+A1:2010+A12:2011
MTBF: 100000 hours minimum at full load at 25 ambient
Life: 3-5 years alternative
Dimension: 98*58*37mm(L*W*H)
Weight: 1380g
Packing: 0.12kg/Pcs;36*23.6*25.5CM/50PCS

 

Details:

 

Model: YSI-0500400 YSI-1200160 YSI-1500133 YSI-2000100 YSI-3600055
DC Voltage: 5V 12V 15V 20V 36V
Rated Current: 4A 1.6A 1.33A 1.0A 0.55A
Current Range: 0-4A 0-1.6A 0-1.33A 0-1.0A 0-0.55A
Rated Power: 20W 19.2W 20W 20W 20W
Ripple & Noise(max.): 100mVp-p 120mVp-p 150mVp-p 200mVp-p 360mVp-p
Voltage Tolerance: ±5% ±5% ±5% ±5% ±5%
Line Regulation: ±3% ±3% ±3% ±3% ±3%
Load Regulation: ±5% ±5% ±5% ±5% ±5%
Setup,Rise,Hold up time: 3 second max./40 MS max./5 MS max. at 100VAC input and output max. load.

UPS Centralized Power Supply Access Control Battery Charge Backup

MORE PRODUCTS

 

 

UPS Centralized Power Supply Access Control Battery Charge Backup

 

ABOUT YINGJIAO

  UPS Centralized Power Supply Access Control Battery Charge Backup

FACTORY&EXHIBITION

  UPS Centralized Power Supply Access Control Battery Charge Backup

CERTIFICATE

  UPS Centralized Power Supply Access Control Battery Charge Backup

SOLUTION

  UPS Centralized Power Supply Access Control Battery Charge Backup

 

TRANSPORT

  UPS Centralized Power Supply Access Control Battery Charge Backup

CONTACT US

 UPS Centralized Power Supply Access Control Battery Charge Backup

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours