Lead Acid/NiCd/ Lithium Everexceed Phase Controlled Rectifier Battery Charger with RoHS

Everexceed Phase Controlled Rectifier Battery Charger with RoHS. Factory direct sales of high-quality lead acid, NiCd, and lithium battery chargers. Fast and efficient charging for all types of batteries.
Request a Quote

PRODUCTS DETAILS

Basic Info.

Model NO.
uXcel Premium
Size
800*800*2000
Certification
RoHS, TUV, CE, Toby
Socket Type
Flexible/ Standard
Recyclable
Recyclable
Transport Package
Cartonbox or Wooden Pallets
Specification
Output voltage 7.2-72V
Trademark
EverExceed
Origin
Shenzhen, China
HS Code
8504409999
Production Capacity
10000

Product Description

12-Pulse 120V Everexceed Regenerator Rectifier Battery Charger Phase Controlled Battery Charger

The EverExceed uXcel range industrial battery charger is the flagship charger of EverExceed Industrial Power solutions. It integrates proven design topology with the latest advanced digital control technology to control the thyristor bridge rectifier and provides the most reliable and trouble-free performance in any electrical and industrial environments.

Lead Acid/NiCd/ Lithium Everexceed Phase Controlled Rectifier Battery Charger with RoHS

Lead Acid/NiCd/ Lithium Everexceed Phase Controlled Rectifier Battery Charger with RoHS


Advantages:
Lead Acid/NiCd/ Lithium Everexceed Phase Controlled Rectifier Battery Charger with RoHS

Large LCD display

 

User friendly operation with large LCD display, optional touch screen with the choices of 8 languages ensure easy maintenance and operation.Smart communication and Remote Monitoring

Lead Acid/NiCd/ Lithium Everexceed Phase Controlled Rectifier Battery Charger with RoHS Leading Technology- 6 or 12 phase controlled Thyristor technology

 

The embedded micro-computer controller processes signals 10 times faster than standard analog methods.

Lead Acid/NiCd/ Lithium Everexceed Phase Controlled Rectifier Battery Charger with RoHS

Isolation transformer

 

Multilingual digital graphic display with embedded event log. Full compatibility with lead-acid and nickel- cadmium batteries, sealed or vented.

Lead Acid/NiCd/ Lithium Everexceed Phase Controlled Rectifier Battery Charger with RoHS

High Reliability and High MTBF 

 

Precise adjustable temperature compensation, robust and unique design allows the charger to continuously operate at 40°C ambient temperature on full load. Natural ventilation and cooling are available on most of the cases.


>Flexible maintenance and Reduced MTTR-The design make it easy for front-access to all vital modules modules of the charger

 

>Versatile constant voltage and constant current charging modes

 

>Smart communication and Remote Monitoring through isolated RS232, RS485, Ethernet. Full data logging
 

>Long design life up to 20+years-system design life up to 20+ years in continuous operation under the condition of appropriate maintenance

 

>Enhanced Robustness - Mechanical design to withstand vertical and horizontal acceleration stress up to 0.5g as standard

Features:

Lead Acid/NiCd/ Lithium Everexceed Phase Controlled Rectifier Battery Charger with RoHS Lead Acid/NiCd/ Lithium Everexceed Phase Controlled Rectifier Battery Charger with RoHS Lead Acid/NiCd/ Lithium Everexceed Phase Controlled Rectifier Battery Charger with RoHS
Flexibly customized
power solutions to perfectly meet the
specific requirements of customer's industrial applications.
Ruggedized solutions
to withstand harsh environments,
extreme temperatures, humidity, dust and vibrations etc. Up to IP55 protection.
Complete power protection solutions
including switchgear,
DC distribution, monitoring suite.
 
Technical parameters:
OUTPUT
Nominal DC voltage 24/48/110/125/220/240/400
Output voltage range 0-1.5×nominal voltage (adjustable)
Nominal DC current 10-1500A
Output current range 0-1.1×nominal current(adjustable)
Voltage stability ±1% in float mode, input within tolerance
Voltage ripple 1% RMS(with battery connected)
Current Limitation Battery current limitation can be adjusted
Filtering  L-C Filter
Output Protection Short Circuit, NH Fuse and Overvoltage protection

 

OPTIONS
Rectifier Other input voltage
Blocking diode
Surge and Lightning protections
Voltage ripple filter
Battery circuit protection box
Battery Battery reversed polarity detection
Battery low-voltage disconnection contactor (LVD)
Battery room temperature sensor
Battery cabinet / rack
Battery monitoring system
Parallel configurations
System Dropping diodes/DC-DC converter
Earth fault monitoring
Internal cabinet lighting
Anti-condensation heater
Output breaker
Front-panel analog meters/digtal meters
DC distribution
Temparature compensation
AC high and AC low alarm/protection
DC high and DC low alarm/protection
AC fault alarm
LED test function
Other frame colour
Mechanical Up to IP55 external
Plate thickness
Galvanized sheet
Front access maintenance
Top cable entry
Special keylock
Specified cabinet identification (tag, nameplate)
Modbus TCP/IP
Communication modbus RTU(RS485)
DNP3.0 protocol
Volt-free contacts
Transducers 4-20mA
Remote monitoring

 

BATTERY
Type Lead acid or nickel cadmium, vented or recombination and Lithium battery

 

COMMUNICATION
Communication RS232, Modbus RTU

 

GENERAL DATA
Operating temperature 0 to 50 °C
Storage temperature -20 to +70 °C
Relative humidity < 95 % non condensing
Operating altitude 1000 m max without derating
Cooling Fan cooling or Natural cooling according to rating
Efficiency 90% according to rating
External protection IP20
Noise
(at 1m in front of the unit)
55 - 65 dB according to rating
Cabinet color RAL 7035
Dimensions Varying according to ratings & options

 

 

STANDARDS
IEC60146-1-1:2009 Semiconductor converters - Specification of basic requirements
IEC62040-1:2008+AMD1:2013
Uninterruptible power systems (UPS) - Part 1-2: General and safety requirements
 for UPS in restricted access locations
IEC62040-2:2006 Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements
IEC61439-1:2011 Low voltage switchgear and controlgear assemblies - Part 1: General rules
IEC60529:1989+
AMD1:1999
Degrees of protection provided by enclosures (IP Code)
IEC60076-11:2004 Power transformers - Part 11: Dry type transformers

 

 

European Directives
Low voltage directive: 2006/95/EC and 2014/35/EU
EMC directive: 2004/108/EC and 2014/30/EU
CE Mark

Application:
The EverExceed uXcel Premium Rectifier Charger range suits all DC applications requiring a large battery back-up:
  1. Power Transmission and Distribution
  2. Continuous process industries
  3. Oil and Gas and Petrochemical industries
  4. Transportation (rail, metro, tramway)
Lead Acid/NiCd/ Lithium Everexceed Phase Controlled Rectifier Battery Charger with RoHS
Lead Acid/NiCd/ Lithium Everexceed Phase Controlled Rectifier Battery Charger with RoHS
 
Why us?  
Reasons you would prefer to buy this power supply products from us 
Service RMA(24/7 pre-sales and after-sales support),OEM,ODM
Quality Highly reliable quality guaranteed by Varta production equipment, German technology, European raw materials
Warranty Standard 2 years, 5+ years upon request
Price Competitive factory Price! Cut down the cost you paid to the middle man
Professional Founded in 1985, 30+ years battery manufacturing experience
Production capacity 3,500,000KVAh per year
Reliable Two R&D centers;
Three major production bases;
Global 500+ dealers/ agents;
Global 100+ offices;
Business coverage 65+ countries around the world
 
Shipping & Payment
Payment T/T,  L/C , Cash, Western Union etc.(flexible payment term can be discussed)
Port Normally Shenzhen China (any sea port upon request)
Delivery  By sea/air/trian/truck transportation
Delivery time Normally 4 weeks ex factory excluding shipping.
Packing: Pack in carton box then pallet (wooden box)



 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours