Basic Info.
Model NO.
LWC22K-380S380-W
Origin
China
Product Description
Product Features:
Body Size: 370x252x158mm
Weight: <25KG
Cooling method: Liquid cooled, flow rate≥10L/min
IPrating : IP67
Support on-line upgrading and fault diagnosisCompatible with single and three phase charging station
Full digital software design, Redundant protection function design
Main Technical Parameters
Items | Technical Specification | Remarks |
Output Power | 22kW | Support single phase 6.6kW |
Input voltage | Three phase: 304-456Vac (L-L, three phase four lines) | Single phase input; 175-265VAC |
Output voltage | 200-450Vdc | |
Max output current | 64A | Single phase input:20A |
Auxiliary power supply | 9-32Vdc | VCC |
Eff. | ≥94% | @nominal voltage |
Voltage accuracy | ±1% | |
Current accuracy | ±3% | |
Low voltage wake-up | 12/24Vdc&200mAmax (WAKE_UP signal) | Wake up BMS/VCU |
Wake-up mode | AC/CC/CP | Support book charging |
Communication | CAN-BUS | |
Static current | ≤2mA | Sleep mode/ consume battery current at stop status |
Working temp. | -40-85ºC | |
EMC | GBT 18387: 2008, EN 55022 | |
Protection | Input OVP, UVP, output OVP, UVP, OTP, OCP, output short circuit protection, communication fault protection |